Latest DES-1111 Practice Tests with Actual Questions

Get Complete pool of questions with Premium PDF and Test Engine

Exam Code : DES-1111
Exam Name : Specialist - Technology Architect, PowerMax and VMAX
Vendor Name : "DELL-EMC"







DES-1111 Dumps DES-1111 Braindumps

DES-1111 Real Questions DES-1111 Practice Test DES-1111 Actual Questions


killexams.com


DELL-EMC


DES-1111


Specialist - Technology Architect, PowerMax and VMAX


https://killexams.com/pass4sure/exam-detail/DES-1111



Question: 111


What is the default data collection interval for TTP collections?


  1. 5 minutes

  2. 10 minutes

  3. 15 minutes

  4. 30 minutes




Answer: C



Explanation:


Reference: https://manpreetstorage.files.wordpress.com/2016/07/vmax-3-solution-design-student_guide.pdf (49)



Question: 112


What needs to be created in BCSD to link multiple SRDF/A sessions?


  1. Composite Group

  2. Logical relationship

  3. Consistency Group

  4. MSC logical relationship




Answer: C



Explanation:


Reference: https://www.scribd.com/document/411415716/vmax-3-solution-design-student-guide-pdf



Question: 113


What is required before a port can be disassociated from an FA emulation on a PowerMax?


  1. The port must not be a member of any Port Group

  2. The port must not belong to an RDF group

  3. All ports on the I/O module must be offline

  4. All ports associated with the FA emulation must be offline




Answer: D



Explanation:


Reference: https://www.dell.com/community/Symmetrix/How-to-change-FA-port-to-RF-port-in-5977/td-p/7162464


Question: 114


At a disaster planning meeting, an architect is presented with the following facts by a client: A Unix host is replicating storage from a Production PowerMax to a VMAX 250FX.

RDF pairs have been split with Production and DR hosts accessing their respective storage. Invalid tracks have started to build against PowerMax and VMAX 250FX.

The client now wants to bring production back to PowerMax, discarding the VMAX 250FX updates while keeping the updates on the PowerMax .


What is the correct action to take?


  1. Failback

  2. Establish

  3. Resume

  4. Failover




Answer: A
Question: 115

A storage administrator is provisioning storage on a PowerMax 2000 array. The application requires fast reads and the highest possible data protection.


Which RAID level should be recommended?


  1. RAID 6 (6 + 2)

  2. RAID 5 (3 + 1)

  3. RAID 6 (14 + 2)

  4. RAID 5 (7 + 1)




Answer: B



Explanation:


Reference: https://www.delltechnologies.com/asset/en-us/products/storage/technical-support/h16891-powermax- family-ds.pdf



Question: 116


A customer is planning to purchase a PowerMax 8000 system with the zEssentials software package. The environment needs to have the ability to rapidly recover from large scale logical corruption using TimeFinder SnapVX.


Which optional software should be recommended to fulfill the requirement?


  1. Product Suite for z/TPF

  2. GDPR

  3. zDP

  4. AutoSwap




Answer: C



Explanation:


Reference: https://www.gotomojo.com/wp-content/uploads/2019/07/Dell-VMAX-All-Flash-Product-Guide.pdf



Question: 117

What is the maximum number of front-end ports that can be configured on a PowerMax 8000? A. 128

  1. 192

  2. 256

  3. 320




Answer: C



Explanation:


Reference: https://www.delltechnologies.com/asset/en-au/products/storage/technical-support/h16739-20PowerMax- 2000-8000-ss.pdf



Question: 118


DRAG DROP


Match each SRDF command with its function.



wrong



Answer: C
Question: 119

SRDF/A has been enabled between two PowerMax arrays. An extended loss of all RDF links occurs. What is the state of the RDF pair after link connectivity is restored?

  1. Split

  2. Failed Over

  3. Suspended

  4. Partitioned




Answer: D



Explanation:


Reference: https://www.delltechnologies.com/asset/en-us/products/storage/technical-support/docu95482.pdf (24)



Question: 120


What is the maximum number of Bricks and drives that can be configured in a VMAX 950?


  1. 8 Bricks and 288 drives

  2. 2 Bricks and 96 drives

  3. 8 Bricks and 1920 drives

  4. 2 Bricks and 100 drives




Answer: A



Explanation:


Reference: https://ucsi.de/docs/DellTech/Dell_Technologies_Portfolio_Poster_Storage_POWERMAX_ISO- A0_v1a_SEP19.pdf



Question: 121


DRAG DROP


Match each item with its description.




Answer: A
Question: 122

Which SRDF/A resiliency feature allows sessions to remain active during transient link outages?


  1. Group-Level Write Pacing

  2. Transmit Idle

  3. Recovery After Link Loss

  4. Failback




Answer: B


Explanation: Reference:

https://www.dell.com/community/s/vjauj58549/attachments/vjauj58549/vmax/838/1/SRDF%20Connectivity.pdf (25)