Question #53 Section 1


What is the maximum number of expansion enclosures that a single Dell EMC PowerStore appliance supports?


  • 2

    3

    4

    6


  • Answer: B Reference:

    https://www.dellemc.com/resources/en-us/asset/data-sheets/products/storage/h18143-dell-emc-powerstore-family-spec-sheet.pdf (1)


    Question #54 Section 1


    While on-site installing a Dell EMC PowerStore T system, the node A embedded module management Ethernet port link LED is off. What does this indicate?


  • Network connection is established

    No network connection is established

    Port speed is 1 GB/s

    Port speed is 10 GB/s


  • Answer: B Reference:

    https://www.dell.com/support/manuals/pk/en/pkbsd1/powerstore-9000t/pwrstr-isg/embedded-module-leds?guid=guid-bc07892c-75cf-43b6- 8f17-

    8a4c49001aeb&lang=en-us


    Question #55 Section 1


    Which network traffic is encrypted using IPsec?


  • OOB network

    ICD network

    Inter-node network

    ICM network


  • Answer: D Reference:

    https://www.dell.com/support/manuals/pk/en/pkbsd1/powerstore-9000t/pwrstr-ntwk-plang/powerstore-t-model-appliance-networks?guid=guid- 97a3e988-c1bc-4f51-a445-3af23f19da1b&lang=en-us


    Question #56 Section 1


    A Storage Administrator wants to upgrade a two appliance Dell EMC PowerStore cluster. Which Commit options need to be chosen to have all appliances upgraded in the last step?


  • Appliance, Cluster

    Appliance, Appliance

    Cluster, Appliance

    Cluster, Cluster


  • Answer: B

    Question #57 Section 1


    Which option is used when running the journalctl command to query log messages regardless of capitalization?


  • option --casesensitive=YES/NO

    option -quotes

    option -ignorecase

    option --casesensitive=TRUE/FALSE


  • Answer: C


    Question #58 Section 1


    A Storage Administrator notices two fans in a Dell EMC PowerStore are faulted. What describes the system behavior in this circumstance?


  • A five-minute timer starts upon the second fan fault and the system shuts down automatically after the timer expires

    CPU clock speed is reduced by 50% to lower internal temperatures and the system continues normal operations

    An increased fan speed signal is sent to the surviving fans and the system continues normal operations

    Upon the second fan fault, all host I/O is terminated immediately and the PowerStore goes through the halt and vault process and shuts down


  • Answer: D


    Question #59 Section 1


    Which network is used for internal communication?


  • Intra-Cluster Data

    Intra-Cluster Management

    NAD Network

    Inter-Node Network


  • Answer: B


    Question #60 Section 1


    What describes Dell EMC PowerStore X power down?


  • PowerStore X node, appliance, or cluster power down is done entirely with vCenter server commands

    Powering down a PowerStore X node, appliance, or cluster is done in the same manner as a PowerStore T

    PowerStore X node, appliance, or cluster power down utilizes the VSi plugin to perform the needed vCenter server operations

    Powering down a PowerStore X node, appliance, or cluster requires additional vCenter server commands


  • Answer: D