Question #53 Section 1
What is the maximum number of expansion enclosures that a single Dell EMC PowerStore appliance supports?
2
3
4
6
Answer: B Reference:
https://www.dellemc.com/resources/en-us/asset/data-sheets/products/storage/h18143-dell-emc-powerstore-family-spec-sheet.pdf (1)
Question #54 Section 1
While on-site installing a Dell EMC PowerStore T system, the node A embedded module management Ethernet port link LED is off. What does this indicate?
Network connection is established
No network connection is established
Port speed is 1 GB/s
Port speed is 10 GB/s
Answer: B Reference:
8a4c49001aeb&lang=en-us
Question #55 Section 1
Which network traffic is encrypted using IPsec?
OOB network
ICD network
Inter-node network
ICM network
Answer: D Reference:
https://www.dell.com/support/manuals/pk/en/pkbsd1/powerstore-9000t/pwrstr-ntwk-plang/powerstore-t-model-appliance-networks?guid=guid- 97a3e988-c1bc-4f51-a445-3af23f19da1b&lang=en-us
Question #56 Section 1
A Storage Administrator wants to upgrade a two appliance Dell EMC PowerStore cluster. Which Commit options need to be chosen to have all appliances upgraded in the last step?
Appliance, Cluster
Appliance, Appliance
Cluster, Appliance
Cluster, Cluster
Answer: B
Question #57 Section 1
Which option is used when running the journalctl command to query log messages regardless of capitalization?
option --casesensitive=YES/NO
option -quotes
option -ignorecase
option --casesensitive=TRUE/FALSE
Answer: C
Question #58 Section 1
A Storage Administrator notices two fans in a Dell EMC PowerStore are faulted. What describes the system behavior in this circumstance?
A five-minute timer starts upon the second fan fault and the system shuts down automatically after the timer expires
CPU clock speed is reduced by 50% to lower internal temperatures and the system continues normal operations
An increased fan speed signal is sent to the surviving fans and the system continues normal operations
Upon the second fan fault, all host I/O is terminated immediately and the PowerStore goes through the halt and vault process and shuts down
Answer: D
Question #59 Section 1
Which network is used for internal communication?
Intra-Cluster Data
Intra-Cluster Management
NAD Network
Inter-Node Network
Answer: B
Question #60 Section 1
What describes Dell EMC PowerStore X power down?
PowerStore X node, appliance, or cluster power down is done entirely with vCenter server commands
Powering down a PowerStore X node, appliance, or cluster is done in the same manner as a PowerStore T
PowerStore X node, appliance, or cluster power down utilizes the VSi plugin to perform the needed vCenter server operations
Powering down a PowerStore X node, appliance, or cluster requires additional vCenter server commands
Answer: D
6$03/( 48(67,216
7KHVH TXHVWLRQV DUH IRU GHPR SXUSRVH RQO\ )XOO YHUVLRQ LV XS WR GDWH DQG FRQWDLQV DFWXDO TXHVWLRQV DQG DQVZHUV
.LOOH[DPV FRP LV DQ RQOLQH SODWIRUP WKDW RIIHUV D ZLGH UDQJH RI VHUYLFHV UHODWHG WR FHUWLILFDWLRQ H[DP SUHSDUDWLRQ 7KH SODWIRUP SURYLGHV DFWXDO TXHVWLRQV H[DP GXPSV DQG SUDFWLFH WHVWV WR KHOS LQGLYLGXDOV SUHSDUH IRU YDULRXV FHUWLILFDWLRQ H[DPV ZLWK FRQILGHQFH +HUH DUH VRPH NH\ IHDWXUHV DQG VHUYLFHV RIIHUHG E\ .LOOH[DPV FRP