DES-1721 Dumps DES-1721 Braindumps

DES-1721 Real Questions DES-1721 Practice Test DES-1721 Actual Questions


killexams.com


DELL-EMC


DES-1721


Specialist - Implementation Engineer, SC Series


https://killexams.com/pass4sure/exam-detail/DES-1721


Question: 106


What are the possible methods to upgrade the firmware on a Brocade switch? A . FTP, SFTP, and Web Tools

B . USB, FTP, and SFTP

C . USB, FTP, and Web Tools D . USB, SFTP, and Web Tools


Answer: C Question: 107 DRAG DROP

You have just deployed an SC Series array in Virtual Port Mode.


What is the correct sequence of steps to perform an array port failover test?



Answer:


Question: 108


What is the maximum number of disks that can be supported by an SC4020 running SCOS 6.6.4 or later? A . 120

B . 128

C . 192

D . 196


Answer: A


Question: 109

A company is using an SC4020 array and the storage administrator wants to expand the available capacity by adding 92, 3.5” disk drives. Which expansion enclosure(s) can be used to meet the demand?

A . 1x SC280 drive bay

B . 2x SC180 drive bays C . 4x SC220 drive bays D . 8x SC200 drive bays


Answer: D


Question: 110


A customer is concerned they are over utilizing their 7K drives. Where can information about the real time I/O usage of individual drives be viewed? A . Hardware > Disks > [disk folder] > [disk number]

B . Charting > Disks > [disk folder] IO Charts

C . Charting > Disks > [disk folder] > [disk number] D . Hardware > Disks > [disk folder]

Answer: A


Question: 111


Based on SAS back-end cabling best practices, which configuration represents how an SC4020 storage array with one SC220 expansion enclosure is cabled?





A . Configuration A B . Configuration B C . Configuration C D . Configuration D


Answer: A

Question: 112


DRAG DROP


What is the correct system hierarchy of SC Series array storage virtualization?



Answer:


Question: 113


Which best practices should be followed when using iSCSI to connect SC Series arrays and hosts for switches that incorrectly negotiate speed and duplex?

A . Use a separate supernet or switches for iSCSI trafficGigabit full duplex hard set for all iSCSI portsEnsure switches used for iSCSI are of a blocking design B . Use a separate VLAN or switches for iSCSI trafficAuto-negotiate for all switchesEnsure switches used for iSCSI are of a non-blocking design

C . Use a separate VLAN or switches for iSCSI trafficGigabit full duplex hard set for all iSCSI portsEnsure switches used for iSCSI are of a non-blocking design D . Use a separate subnet or switches for iSCSI trafficAuto-negotiate for all switchesEnsure switches used for iSCSI are of a blocking design

Answer: C


Question: 114


A customer wants to add an iSCSI path to a Microsoft Windows Server 2012 R1. The server has an existing Fibre Channel path to an SC7020 array for load balancing and high availability.


Which Windows MPIO policy should be configured to achieve the customer’s requirement? A . Fail Over Only

B . Weighted Paths

C . Round Robin with Subset D . Round Robin


Answer: D


Question: 115


Based on documented best practices, which options may need to be modified on a server QLogic HBA? A . Port Down Retry Count and Enable LIP Reset

B . Enable Target Reset and Login Retry Count

C . Port Down Retry Count and Enable Target Reset D . LUNs Per Target and Port Down Retry Count


Answer: C


Question: 116


What is the maximum memory supported on a single SC9000 controller? A . 64 GB

B . 96 GB C . 128 GB D . 256 GB


Answer: D


Question: 117

A customer wants to configure a threshold alert definition. Which types of definitions can be configured?

A . Latency, Disks, and Replication

B . Storage, Latency, and Disks

C . Storage, Replication, and Hardware D . I/O Usage, Storage, and Replication


Answer: D

Question: 118


Which method can be used to identify the server HBA WWN? A . Brocade Web Tools “Port Admin” tab

B . Dell Storage Manager Data Collector C . Dell Storage Manager Client

D . QConverge Console GUI


Answer: C


Question: 119


Which 64-bit server operating systems are compatible with the Dell Storage Manager (DSM) Client? A . Red Hat Enterprise Linux 6, Windows Server 2012 R2, and Windows Server 2008 R2

B . Windows Server 2008 R2, Windows Server 2012 R2, and Windows 2016

C . Windows Server 2008 R2, Red Hat Enterprise Linux 7, and Windows Server 2012 R2 D . Red Hat Enterprise Linux 6, Windows Server 2016, and Windows Server 2008 R2


Answer: C


Question: 120


Which zones accurately describe the zoning requirement for replication connectivity to be established when the source array is in Legacy Port Mode and the target array is in Virtual Port Mode?

A . Zone 1 = All Source Virtual Port WWNs + All Remote Physical Port WWNsZone 2 = All Source Physical Port WWNs + All Remote Virtual Port WWNs B . Zone 1 = All Physical WWNs from both arraysZone 2 = All Virtual WWNs from both arrays

C . Zone 1 = All Source WWNs + All Remote Virtual Port WWNsZone 2 = All Source WWNs + All Remote Physical Port WWNs

D . Zone 1 = All Source Virtual Port WWNs + All Remote Port WWNsZone 2 = All Source Physical Port WWNs + All Remote Port WWNs


Answer: B


Question: 121


You are installing a new SC9000.


Which procedure should be used to install and configure the system? A . Connect through the iDRAC port

B . Connect through a null modem cable to the serial port C . Connect through the Dell Storage Manager Client

D . Connect through the supplied proprietary serial cable to the serial port


Answer: D