Exam Code : HPE0-S60
Exam Name : HPE ASE - Compute Solutions
Vendor Name :
"HP"
HPE0-S60 Dumps HPE0-S60 Braindumps
HPE0-S60 Real Questions HPE0-S60 Practice Test HPE0-S60 Actual Questions
killexams.com
HPE ASE - Compute Solutions
https://killexams.com/pass4sure/exam-detail/HPE0-S60
Which compute node parameters are captured within server hardware type?
Number of the CPUs
installed operating system
Mezzanine card configuration
Size of the memory Installed
You need to setup HPE Synergy frames after hardware components are discovered within HPE OneView. Put the steps to achieve this goal into the coned order in the answer area on the right.
Which statement about manual orchestration during the firmware update is true?
It is supported only for logical enclosures with at least three frames
It provides an ability to select and update one side of the Interconnect topology at a time
It provides the ability to install an older firmware version than currently Installed In the interconnect
It allows all the interconnect modules to be activated manually at the same time.
Which statement about the HPE D3940 storage module is true?
SATA drives requires redundant 10 adapters to be installed in this module
Up to five modules can be installed in a single frame with Gen10 servers
it is configured through CLl available from HPE Synergy console
Only one type of drives (SATA, SAS, SSD) can be installed in each module
Your customer has 6 logical enclosures spanning 18 HPE Synergy frames. The customer needs to add one more logical enclosure based on 5 HPE Synergy frames
How will this change impact the customer environment?
The customer can add a new logical enclosure to the existing setup because the maximum number of logical enclosures in a single management ring is not reached.
The customer has to expand the management ring capacity either by adding HPE Composer 2 modules or adding memory to reach 128GB per module.
The customer has to create a new management ring for new logical enclosure because the maximum number of frames m a single management ring is reached.
The customer can add a new logical enclosure to an existing setup once all required licenses are added lo HPE OneView and associated with the new frames.
Your customer plans to deploy VMware vSAN using D3940 Storage Modules. Which statement about this solution is true?
The 12Gb SAS modules required for D3940 connectivity can only be installed in the first fabric.
To use the storage controller that will access D3940 storage modules, a second CPU must be installed.
For VMware vSAN deployment, all drives in the D3940 storage modules must be SSD drives.
All drives in the D3940 storage modules must formulate a single logical drive with RAID5 configured
Your customer wants to add dedicated Fibre Channel connectivity to the HPE Synergy frame running HPE Synergy 480 Gen10 compute modules, each with one CPU socket populated Currently they use two 12 Gb SAS switches and two HPE Virtual Connect SE 100Gb F32 Modules for HPE Synergy installed in third fabric.
What must be done to enable dedicated FC connectivity for this HPE Synergy frame?
A second CPU must be installed for all HPE Synergy 480 Gen10 compute nodes.
For Brocade switches, a logical interconnect group must be created in HPE OneView.
For VC-FC modules, all of server facing ports must be property licensed.
SAS switches must be moved to second fabric and FC modules Installed in the first one.
You are troubleshooting an HPE OneView server profile that presents a critical state. The server profile was configured with a Link Aggregation Group
What should you check to fix the issue?
if both FiexNICs are configured with the same speed
If the logical enclosure is built on at least three HPE Synergy frames
if both FiexNICs are connected to different networks
if the logical enclosure is configured with redundant master modules
Your customer plans to expand an existing nPar based on a single HPE Superdome Flex chassis. Which statement about workload availability during expansion is true?
Powered nPar can be expanded only if HPE Superdome Flex 280 is used
Online expansion is available only if RMC is used for management.
HPE Superdome Flex does not support expansion of powered on nPars
Powered nPar can be expanded if it does not use HPE Persistent Memory
Which tool can be used to evaluate me health of an HPE Oneview appliance before proceeding with an appliance updated.
HPE Composer Maintenance Console
HPE OneView Update Readiness Checker
HPE OneView Global Dashboard
HPE OneView Firmware Compliance Report
A logical interconnect group can span on multiple HPE Synergy frames for which interconnect type?
Brocade 32GB Fibre Channel Switch Module for HPE Synergy
HPE virtual Connect SE 32 Gb FC Module for Synergy
HPE Virtual Connect SE 100 Gb F32 Module tor Synergy
HPE Synergy 12 Gb SAS Connection Module
Your customer manages HPE Synergy using HPE OneView. For one of its projects, the company purchased 50 HPE. ProLiant DK385 Gen10 Plus v2. They plan to manage the new systems using HPE OneView as well.
What should the customer do to manage rack system using HPE OneView?
add the rack system to the HPE OneView instance used to manage HPE Synergy to centralize management of all systems.
connect the rack system to an IPDU and add the IPDU to the HP
OneView instance that is used for HPE synergy management.
Deploy HPE OneView Global Dashboard and add the rack systems there, as AMD systems are not directly in HPE OneView.
Deploy an HPE OneView virtual appliance, and, after configuration, use it to manage only the rack systems.
Match each HPE OneView network type with its definition.
Which statement about a new HPE SimpliVity deployment is true?
New HPE SimpliVity deployments gives customer flexible choice of hypervisor
A new HPE SimpliVity node can be a member of multiple dusters
AM new HPE SimpliVity models are software optimized
All new HPE SimpliVity models are based on mid CPUs
You plan to configure a Link Aggregation Group (LAG) for two connections within a server profile for a compute node running an ESXI system.
What is required from the VMware side to enable LAG?
Virtual Distributed Switch
vSphere Standard license
Load balancing cluster
Dedicated VMKernel port
In the past a customer experienced a networking issue where network ports went down and came back up in quick succession.
Which HPE Virtual Connect SE 100 GD F32 Module for HPE Synergy feature can be configured to disable such ports?
Pause flood protection
sFlow
Storm control
Port flap protection
Your customer reports mat an external FC boot volume for Windows server is visible four times in the Disk Management 1 online and 3 offline.
What should you do to resolve this issue?
Disable deduplication for this volume at the array level
Remove the offline disks using array management tools
Install and configure MPIO on me Windows system
Remove the offline disks using Windows Disk Management
Your customer plans to use HPE Primera to boot HPE Synergy compute nodes. They currently have two HPE Virtual Connect SE 100Gb F32 Module for Synergy modules installed in the frame. The customer wants to use FC as a storage access protocol
What must be done to complete this task?
Enable FC primary and secondary boot on the modules through the HPE OneView interface
FC connectivity on the modules should be enabled through the service console by disabling FCo
Add FC upgrade licenses in HPE OneView that will enable FC connectivity for the modules
Enter both modules into a maintenance mode, then enable FC connectivity through CLI
You modified a logical interconnect group mat is used to configure logical interconnects in five different logical enclosures.
What will be the impact of that change?
All physical interconnects from affected logical interconnects will be placed in a maintenance mode
All physical interconnects from the affected logical interconnects must he rebooted to activate the new configuration
All logical interconnects configured using this logical Interconnect group will report inconsistency
All logical interconnects configured using this logical interconnect group will be automatically updated
Which statement about login redistribution is true?
Login redistribution is available only If HPE Primera or HPE Alletra is connected directly to the HPE Synergy frame
Login redistribution is a licensed feature and the number of licenses required depends on the number of active ports
Login redistribution is supported only on the HPE Synergy Virtual Connect SE 32Gb FC Modules
Login redistribution is used for login balancing when they are not distributed evenly over the FC links
Which statement about an HPE Oneview support dump is true?
Appliance support dump by default contains a logical enclosure support dump
Support dump is a binary file that can be opened only in a dedicated application
Support dump can be created if HPE Virtual Connect modules are installed in the frame
Preview support dump is available only when creating an appliance support dump
Your customer plans to add four HPE Synergy frames to an existing management ring Ail installed frames are equipped with two 2-port FLM modules, while new frames will be equipped with 4-port FLM modules.
Which statement about mixing different FLM modules is true?
Existing 2-port FLM modules must be replaced with 4-port FLM modules
A management ring can contain mixed frame link module configurations
A management ring with mixed FLM modules cannot have more than 12 frames
Mixing different FLM modules is allowed if all of them have the same firmware version