Question: 35


The cost of qualified Coating Inspection is normally offset by:

  1. Lower Application Costs

  2. Lower Coating Life Cycle Costs

  3. Lower Safety Enforcement Costs

  4. Lower Supervision Costs


Answer: B


Question: 36


When environmental enclosures are being used an inspector needs to be concerned about:

  1. Lighting

  2. Air changes

  3. Structural integrity

  4. a), b), and c)


Answer: D


Question: 37


Eddy current DFT gauges are used to measure Dry Film Thickness in which of the following situations:

  1. Magnetic coatings applied to a magnetic metallic substrate

  2. Non-Conductive coatings applied to a conductive metallic substrate

  3. Conductive coatings applied to a magnetic metallic substrate

  4. Conductive coatings applied to a cementitious substrate


Answer: B


Question: 38


A single component water borne acrylic coating cures by:

  1. Solvent Evaporation

  2. Coalescence

  3. Co-Reaction

  4. Oxidation

Answer: B


Question: 39


The best choice of instrument for holiday testing of thick film concrete coatings is:

  1. Low Voltage Sponge Type

  2. High Voltage DC Pulse Type

  3. High Voltage DC Constant Current

  4. High Voltage AC


Answer: C


Question: 40


The most likely area of failure on a buried external pipeline coating is the:

  1. Mainline coating

  2. Field joint coating

  3. Areas exposed to Ultra Violet light

  4. Ground bed


Answer: B