NCIDQ Dumps NCIDQ Braindumps

NCIDQ Real Questions NCIDQ Practice Test NCIDQ Actual Questions


CIDQ


NCIDQ


National Council for Interior Design Qualification


https://killexams.com/pass4sure/exam-detail/NCIDQ


Question: 147


Specifications can be made most concise by


  1. Avoiding the use of words like a, the, and all

  2. Using descriptive specifications

  3. Using phrases instead of complete sentences

  4. Using reference standard specifications


Answer: C


Question: 148


Which design elements could be used to lower the apparent height of a ceiling?


  1. A dark, highly textured ceiling

  2. A light ceiling and textured walls

  3. Strong horizontal lines on the walls

  4. Fine-grained patterns on the ceiling and dark walls


Answer: A


Question: 149


To minimize conflicts in the contract documents, what is the LEAST important action the interior designer can take?


  1. Make sure terminology in the specification is the same as in the drawings

  2. Show only dimensions on the drawings

  3. Have someone check the drawings before they are issued

  4. Write the specification after the drawings are essentially complete

Answer: D


Question: 150


A window covering that is made from fabric and generally not intended to be opened is called


  1. An Austrian shade

  2. Drapery

  3. A curtain

  4. A vertical blind


Answer: C


Question: 151


To detail a doorframe for a conference room where privacy is critical, which of the following is LEAST likely to be required?


  1. An automatic door bottom

  2. A heavy-duty, silent door closer

  3. A solid-core door

  4. Neoprene gasketing


Answer: B


Question: 152


What type of resilient flooring would be the best choice for a commercial kitchen?


  1. Sheet vinyl

  2. 1/8 in (3) commercial grade vinyl tile

  3. Sheet rubber

  4. Heavy-duty cork flooring


Answer: A


Question: 153


What symbol is used to indicate a floor-mounted telephone outlet?


  1. A

  2. B

  3. C

  4. D


Answer: C


Question: 154


Which of the following would be the LEAST desirable choice for a carpet installation for hotel rooms that have concrete subfloors?


  1. Wool carpet direct-glued

  2. Nylon carpet stretched in over a foam cushion

  3. Acrylic carpet direct-glued

  4. Polyester carpet stretched in over a felt cushion


Answer: A


Question: 155


What is NOT required on a 1-hour rated door


  1. Panic hardware

  2. Ball-bearing hinges

  3. Door closer

  4. Metal frame


Answer: A


Question: 156


What type of schedule would be LEAST likely to be found in a set of interior or design drawings?


  1. Millwork schedule

  2. Window schedule

  3. Finish schedule

  4. Equipment schedule


Answer: B


Question: 157


Wallpaper is most useful to a designer in creating


  1. Line

  2. Scale

  3. Pattern

  4. Texture


Answer: C